AI GxP validation for regulated life sciences
SCADA / DCS Validation

Wonderware, Ignition, DeltaV, Experion — validated for GMP.

Historian, alarms, batch, HMI — validated with data-integrity and cyber-hygiene bundled in.

Quick chat on WhatsAppHuman review at every gateISO 9001 & 27001 certified
SCADA validationDCS validationDeltaV validation
A controlled validation document in GxP Copilot
Signed deliverablesControlled and versioned
Human reviewAt every gate
In short

SCADA and DCS validation covers the control systems running manufacturing and utilities — alarm handling, interlocks, trending, historian data and the integrity of what reaches the batch record. The software component is categorised under GAMP 5; the equipment it controls is qualified against EU GMP Annex 15, with critical process parameters carried into the challenge tests.

SCADA scope + risk
Alarm & historian validation
Cyber-hygiene baseline

Outcomes you can expect

  • SCADA scope + risk
  • Alarm & historian validation
  • Cyber-hygiene baseline

SCADA / DCS Validation is delivered by our validation & compliance services practice. Where it saves time, the team uses our products: GxP Copilot for validation lifecycle work and TraceDraft for clinical documentation.

Explore related capabilities: Computer System Validation (CSV), Computer Software Assurance (CSA), AI Validation Services (Annex 22), FDA 21 CFR Part 11 Compliance.

SCADA and DCS in GMP: The Historian and Alarm Record Challenge

SCADA and Distributed Control Systems are GxP-critical when they directly control GMP manufacturing processes — fermentation, filling, sterilisation, environmental monitoring — and generate electronic records of those processes. The two SCADA functions that generate the most validation and data integrity scrutiny are the process historian and the alarm management system. The historian records all process parameter values with timestamps; the alarm management system records all process parameter excursions, their detection, and their acknowledgement. Both are primary GMP records for batch release and regulatory inspection.

The most common historian data integrity failure in SCADA validation is timestamp accuracy: historian timestamps that are derived from individual workstation clocks rather than a synchronised NTP time server create irreconcilable discrepancies between the historian record and other GMP system records (MES, LIMS) that independently record the same process period. This discrepancy is not a technical nuisance — it is a data integrity finding that calls the reliability of the entire historian record into question. Our SCADA validation includes specific time synchronisation verification as a standard protocol element.

ELN
LIMS
MES
ERP
CompleteAttributableUnchanged
Each system can be validated and the data can still break between them. Every handoff needs its own check that the data arrived complete, attributable and unchanged.
Have a system going live?Talk to a validation lead, or chat with us on WhatsApp.

Cyber-Hygiene as a GxP Validation Element

SCADA and DCS cybersecurity is no longer separate from GxP validation — it is a GxP validation requirement. Both FDA and EMA have published guidance that links cybersecurity to data integrity: a GxP system that can be accessed by unauthorised users, or whose historian records can be modified by an undetected intrusion, does not meet the data integrity requirements of EU GMP Annex 11 and 21 CFR Part 11. Cyber-hygiene baseline documentation — network segmentation, patch management status, antivirus or application whitelisting, remote access controls, and physical access controls to the OT network — is therefore part of the SCADA validation package.

Our SCADA validation bundles a cyber-hygiene baseline assessment with the standard IQ/OQ/PQ execution. The assessment documents the current network segmentation between the corporate IT network and the OT network, the patch management status for all SCADA components, the remote access protocol and its authentication controls, and the physical access controls to control room and field device locations. Where gaps exist against NIST CSF or IEC 62443 baselines, we produce a prioritised remediation plan that QA and IT can address collaboratively.

SCADA validationDCS validationDeltaV validationCSV servicesCSA servicesAI validation servicesFDA compliance servicesGAMP 5 consultingIQ OQ PQ servicesLIMS validationSAP validationOracle validationMES validationcloud validationsupplier qualificationdata integrityaudit readiness

See it on your own system.

Bring a URS or a system. We show you the validation package it produces.

  • We reply within one business day
  • We run your URS live on the call
  • You get a clear plan and scope
Chat on WhatsApp

Talk to a validation lead

Four fields. The right specialist replies within one business day.

Your details stay private. We never share them.